WAKOL MS 228

Valmis elastiline paigaldusliim

WAKOL MS 228 Ready-to-lay Parquet Adhesive,
elastic
Technical Information
Area of application
Elastic, 1 component parquet adhesive for laying
 multi-layer parquet according to DIN EN 13489
on absorbent and non-absorbent subfloors indoors.
In connection with WAKOL Speciality Trowel 5 suitable as an adhesive with an integrated
moisture barrier exclusively for types of parquet with tongue and groove joint on unheated
cement screeds up to 4 CM% or 85% corresponding relative humidity.

solvent-free according to the definition of
TRGS 610

suitable for underfloor heating
water-free – no wood swelling
Complies with DIN EN 14293
1) Based on the criteria of GEV (Association for Emission-controlled Laying Materials), classified as EMICODE EC1 PLUS R: very low in emissions
2) Emission class according to French law
Technical data
Raw material basis: Silane-modified polymer
Airing time: none
Open time: approx. 40 minutes
Setting time: approx. 24-48 hours
Cleaning agent: WAKOL RT 5960 Cleaning Cloths before adhesive sets
Storage: 12 months at room temperature
Storage temperature: not sensitive to frost
GISCODE: RS10
EMICODE according to GEV: EC1 PLUS R

Application and consumption m3:
TKB B3 800 – 1000 g/m² Small-sized multi-layer parquet
TKB B11 1000 – 1200 g/m² Small-sized multi-layer parquet
TKB B13 1100 -1300 g/m² Large-sized multi-layer parquet
TKB B15 1400 – 1500 g/m² Large-sized multi-layer parquet
WAKOL Speciality Trowel 5  – 1700 – 1800 g/m² Multi-layer parquet up to max. 4 CM% or 85%
corresponding relative humidity
3) Consumption is dependent on surface structure and absorbability of subfloor
Subfloors
The subfloor and the climatic conditions of the room must meet the requirements of DIN
18356. Subfloors must be permanently dry, solid, level and free from cracks, dirt and
adhesion-inhibiting substances.
Mechanically pretreat and thoroughly vacuum-clean calcium sulphate concrete according to
manufacturer’s specifications or according to the applicable standards and codes. Once the
concrete subfloor is free of dust, the parquet may be bonded directly with WAKOL MS 228
Ready-to-lay Parquet Adhesive, elastic. Do not apply WAKOL MS Ready-to-lay Parquet
Adhesive, elastic to cast asphalt; prior consult our technical department.
Do not apply WAKOL MS 228 Ready-to-lay Parquet Adhesive, elastic directly to WAKOL PU
280 Polyurethane Primer or to WAKOL PU 235 Polyurethane Primer.
WAKOL MS 228 Ready-to-lay Parquet Adhesive, elastic can be used as moisture barrier on
unheated cement screeds up to 4 CM% or 85% corresponding relative humidity. In this
application, laying has to be done with WAKOL Speciality Trowel 5.
Usage
Using a notched trowel, apply uniformly on the subfloor, avoiding adhesive pools.
Immediately insert the parquet and press down firmly. Ensure that the underside of each
wooden element is sufficiently coated with adhesive.
Immediately after using, clean tools with WAKOL RT 5960 Cleaning Cloths. After hardening,
WAKOL MS 228 Ready-to-lay Parquet Adhesive, elastic can be removed only mechanically.
Important
Do not use at temperatures below +15°C. In cold weather, warm up WAKOL MS 228 Readyto-
lay Parquet Adhesive, elastic in due time in heated room. All information is based on
approx. 20°C and 65% relative air humidity.

Do not apply WAKOL MS 228 Ready-to-lay Parquet Adhesive, elastic directly to cast asphalt,
to WAKOL PU 280 Polyurethane Primer or to WAKOL PU 235 Polyurethane Primer.
We guarantee the uniform high quality of our products. All data is based on tests and many
years of practical experience and refers to standardised conditions. The variety of materials
used and the different construction site conditions, which lie beyond our control, preclude any
claims based on this data. We therefore recommend making sufficient trials. Accompanying
flooring manufacturer’s instructions and the currently applicable standards and codes must
be observed. We gladly provide technical advice.
The product data sheets can be found in their latest version at www.wakol.com.
When this Technical Information bulletin dated 07.07.2014 is issued, all previous versions
cease to be valid.